API 661
10.2.6
If the plates are not fully examined for laminations by ultrasonic examination and if set-on connections are used, the edge of the hole in the plate to which the connections are attached shall be examined for laminations by magnetic particle or liquid penetrant. indications found shall be cleared to sound metal and than back-welded.